Skip to content

Home / Products / NAU-Clean PowerSafe

Patented formula

Panel cleaning

NAU-Clean NS020 20 litre drum with NA360 and NA500 aerosol sprays

NAU-Clean

NAU-Clean PowerSafe

Clean live panels without cutting power

NAU-Clean is a non-conductive, residue-free cleaning solution for electrical and electronic systems. It removes dust and grime from energized control panels, PLCs and switchgear, so cleaning no longer needs a shutdown.

Why it matters

Don’t let dust spark a disaster.

Dust settles on every busbar, breaker and terminal. In a live panel it holds heat and moisture and creates tracking paths, so regular cleaning is basic fire prevention.

Electrical control panel with contactors, breakers and wiring that needs regular cleaning

Fire safety

Prevents electrical fires

Dust and debris inside panels trigger sparks and overheating that can start a fire.

Asset life

Longer equipment life

Clean components run cooler and last longer, with less wear and fewer replacements.

Uptime

Fewer unexpected breakdowns

Regular cleaning cuts the risk of sudden outages and lost production.

Compliance

Audit-ready panels

Maintained panels meet safety standards and pass inspections easily.

Efficiency

Lower energy losses

Clean systems waste less energy and help equipment perform as designed.

Maintenance

Problems caught early

Routine checks and cleaning let you fix minor issues before they become major ones.

Clean smarter, not harder

Traditional cleaning vs NAU-Clean

Air blowing, diesel, thinner and cloth wiping were never meant for live electrical equipment. Here is how they compare.

Traditional cleaning
VS
Cleaning with NAU-Clean
Air blowing, diesel, thinner, cloth wiping
Cleaning method
Purpose-built electrical cleaning agent
High fire and electric shock risk
Safety
Non-conductive and safe when used correctly
Oily or sticky residue remains
Residue
No residue, dry finish
Dust pushed deeper into components
Effect on dust
Dust dissolved and flushed out
Risk of damage to VFDs, PLCs and relays
Electronics
Safe for sensitive electronics
Very high (flammable liquids)
Fire risk
High ignition point, low fire risk
Degrades insulation over time
Insulation
Maintains insulation integrity
Long and unpredictable
Downtime
Minimal, panels stay energized
Non-standard and inconsistent
Repeatability
Professional, repeatable process
Often fails safety audits
Audits
Supports safety and maintenance standards

Why choose NAU-Clean

More than a cleaner: preventive maintenance.

Every benefit adds up to higher safety, reliability and efficiency for your electrical infrastructure.

Non-conductive and live-safe

Use on live panels without risk of short circuits, tested up to 100 kV.

Zero-downtime maintenance

Clean energized systems without shutting down operations.

Residue-free cleaning

Evaporates fully with no moisture or film, so there is no wiping or drying.

Non-corrosive formula

Gentle on components; does not harm metal parts, plastics or insulation.

High fire safety

A high ignition point (about 265 °C) greatly reduces fire risk while cleaning.

Eco-friendly and certified

Free of CFCs and green-certified, safe for workers and the environment.

Longer equipment life

Prevents dust-induced failures and overheating, so systems last longer.

Compliance and audit readiness

Keeps panels inspection-ready and in line with electrical safety standards.

Two formats

The right format for every job.

Aerosol cans for routine clean-ups of smaller equipment, and a liquid cleaning agent for plant-scale maintenance with spray equipment.

NAU-Clean NA500 and NA360 aerosol cleaner cans for electrical equipment

Aerosol spray

For distribution boards, control panels, PLCs, PCBs, inverters and small motors. Spray directly onto the equipment.

NAU-Clean NS020 liquid cleaning agent in a 20 litre drum

Liquid cleaning agent

For transformers, switchgear, VCB, ACB and MCCB panels, busbars and rectifiers where a shutdown is difficult.

Panel cleaning, simplified

Inspect, clean in three stages, verify.

A standard method, so every panel is cleaned the same way and every visit can be logged for audits.

Inspect

A thermal imaging camera finds hot spots before cleaning. PPE on.

High-pressure clean

Transformers and VCB panels: high-pressure NAU-Clean spray.

Low-pressure clean

ACB and MCCB panels: gentle low-pressure spray.

Air-blow finish

PLC and control panels: air blowing clears loosened dust.

Verify

Enclosure wiped down, then a final thermal scan confirms the result.

Technician inspecting an electrical panel with a thermal imaging camera
Technician cleaning an energized switchgear panel with a high-pressure NAU-Clean spray

Where it is used

Built for sites that can’t switch off.

Anywhere live electrical maintenance matters, from metro systems to hospitals and data centres.

Proven and certified

Patented technology, tested to 100 kV.

NAU-Clean is made by NAUMADE Co., Ltd. in South Korea. Its insulation-cleaner formula for live high-voltage and communication equipment is patented with the Korean Intellectual Property Office.

Korean Intellectual Property Office patent certificate 10-2506955 and NAUCLEAN trademark registration 40-1513814

100 kV

Dielectric breakdown voltage, tested

~265 °C

Auto-ignition point, for high fire safety

Zero

Residue and corrosion after cleaning

20 L

Drum for plant-scale cleaning

Ready to clean without a shutdown?

Tell us what you need to clean and how often. We will recommend the right format and quantity for your site.

Chat with an engineer
SPID Solutions at ISEE – The E&E Show, 3–5 December 2026, Stall 2D32, Yashobhoomi Convention Centre, New Delhi

Meet us in New Delhi

ISEE – The E&E Show 2026 · Stall 2D32

  • 3–5 December 2026
  • Yashobhoomi Convention Centre, Dwarka, New Delhi